常(chang)見問題(ti):
|
數(shu)顯(xian)表(biao)黑(hei)屏 | 1.數(shu)顯(xian)表(biao)可能(neng)處(chu)於休(xiu)眠狀(zhuang)態,按任意(yi)鍵使數顯(xian)表(biao)回(hui)到(dao)正(zheng)常(chang)工(gong)作(zuo)狀態; 2.檢(jian)查(zha)數(shu)顯(xian)表(biao)的電(dian)源線插頭(tou)是(shi)否(fou)插好; 3.檢(jian)查(zha)電(dian)源線是(shi)否(fou)有(you)損傷; 4.檢(jian)查(zha)開(kai)關(guan)電(dian)源的輸(shu)出(chu)電(dian)壓是(shi)否(fou)在 15-24VDC±10%的範(fan)圍內。
|
|
數(shu)顯(xian)表(biao)在工(gong)作(zuo)過(guo)程(cheng)中(zhong) 經(jing)常(chang)自(zi)己(ji)重(zhong)啟
| 1、供(gong)電(dian)電(dian)壓太低(di)或(huo)者(zhe)電(dian)壓不穩(wen); 2、檢(jian)查(zha)開(kai)關(guan)電(dian)源的輸(shu)出(chu)電(dian)壓是(shi)否(fou)在 15-24VDC±10%範(fan)圍內; 3、檢(jian)查(zha)各(ge)個電(dian)源插頭(tou)連(lian)接是(shi)否(fou)良(liang)好。 |
| 數(shu)顯(xian)表(biao)跳(tiao)大數 或(huo)者最後(hou)幾(ji)位抖動(dong) | 1、檢(jian)查(zha)數(shu)顯(xian)表(biao)是(shi)否(fou)接地,接地是(shi)否(fou)良(liang)好; 2、檢(jian)查(zha)所(suo)有(you)電(dian)纜連接器(qi)是(shi)否(fou)有(you)松(song)動(dong)或 接觸不良(liang)現象(xiang); 3、檢(jian)查(zha)球柵傳感器(qi)和(he)信號(hao)延(yan)長線是(shi)否(fou)有(you)故(gu)障(zhang)。 |
| 按(an)下按鍵時數顯(xian)表(biao)無(wu)反(fan)應
| 1、面(mian)板發(fa)生(sheng)故(gu)障(zhang); 2、拔掉電(dian)源插頭(tou),15 秒(miao)後(hou)重(zhong)新(xin)上電(dian)。 |
|
數(shu)顯(xian)表(biao)顯(xian)示(shi)“NO SIG” 或(huo)“SIG FAIL” | 1、檢(jian)查(zha)數(shu)顯(xian)表(biao)是(shi)否(fou)連(lian)有(you)傳感器(qi); 2、檢(jian)查(zha)傳(chuan)感器(qi)、電(dian)纜以及(ji)連接器(qi)是(shi)否(fou)有(you)損傷; 3、給(gei)數顯(xian)表(biao)斷電(dian),重(zhong)啟; 4、拔掉該(gai)軸(zhou)的傳(chuan)感器(qi)接頭(tou)換(huan)到另外壹軸,判(pan)斷是(shi)數顯(xian)表(biao)的故(gu)障(zhang)還(hai)是(shi)傳感器(qi)故(gu)障(zhang)。 |
|
數(shu)顯(xian)表(biao)讀(du)數(shu)有(you)誤差
| 1、檢(jian)查(zha)傳(chuan)感器(qi)類型設置是(shi)否(fou)正(zheng)確(que); 2、檢(jian)查(zha)該(gai)軸(zhou)的直(zhi)徑(jing)/半(ban)徑讀(du)數(shu)設置,當(dang)設為(wei)直徑時(shi),數顯(xian)表(biao)讀(du)數(shu)是(shi)實際(ji)值的兩(liang)倍; 3、檢(jian)查(zha)誤差補(bu)償系數(shu)是(shi)否(fou)過(guo)大; 4、若使用(yong)了分段(duan)誤差補(bu)償,請(qing)核(he)實確(que)認補(bu)償數據(ju); 5、拔掉該(gai)軸(zhou)的傳(chuan)感器(qi)接頭(tou)換(huan)到另外壹軸,判(pan)斷是(shi)數顯(xian)表(biao)的故(gu)障(zhang)還(hai)是(shi)傳感器(qi)故(gu)障(zhang); 6、檢(jian)查(zha)傳(chuan)感器(qi)或電(dian)纜是(shi)否(fou)損(sun)傷; 7、檢(jian)查(zha)球柵尺(chi)或讀數(shu)頭(tou)安(an)裝是(shi)否(fou)符(fu)合安(an)裝說(shuo)明書規定(ding); 8、松(song)開(kai)兩(liang)端(duan)尺(chi)支架(jia)的緊(jin)固(gu)螺(luo)釘,輕(qing)輕(qing)左(zuo)右移(yi)動(dong)球柵尺(chi),根據移(yi)動(dong)的阻(zu)力(li)判(pan)斷球柵尺(chi)或讀數(shu)頭(tou)上(shang)是(shi)否(fou)有(you)異(yi)物(wu); 9、取(qu)出(chu)球柵尺(chi)放(fang)到(dao)機(ji)床(chuang)導軌或其他(ta)平臺(tai)上(shang),輕(qing)輕(qing)滾動(dong)尺(chi)身(shen),判(pan)斷球柵尺(chi)是(shi)否(fou)有(you)彎曲現象(xiang)。 |
交換(huan)傳感器(qi)進(jin)行故(gu)障(zhang)跟蹤(zong):
1.斷開(kai) NMS300 電(dian)源;
2.斷開(kai)傳(chuan)感器(qi)與(yu)故(gu)障(zhang)軸的連(lian)接,並(bing)移(yi)動(dong)到另(ling)壹軸;
3.重(zhong)新(xin)連接 NMS300 電(dian)源並(bing)打(da)開(kai);
若故(gu)障(zhang)停留在相同(tong)的傳(chuan)感器(qi)上,則(ze)傳(chuan)感器(qi)出(chu)現故(gu)障(zhang)。若故(gu)障(zhang)未隨傳感器(qi)遷(qian)移(yi),則(ze) NMS300 數(shu)顯(xian)表(biao)故(gu)障(zhang)。